| Maximum 2 amps |
| Ground connection required |
| Sensor does not detect motion through glass |
|
Troubleshooting |
| Problem: Cannot switch power on or off with a newly installed sensor switch |
| This sensor requires a true earth ground connection in order to operate properly. First ensure that the device's green and bare wires are connected to the ground in your wallbox. If you do not have a ground available, this device will not function properly. If you do have a ground but are still experiencing this issue, it's possible that your ground wire does not directly return to your breaker panel. In that situation a true earth ground connection would need to be introduced, or this device may not function properly. If you believe this is the issue, contact Lutron's support line at 844-LUTRON1 |
| Problem: Lights do not turn on when space is occupied |
| This is a vacancy only sensor |
| Sensor is set to one of the Ambient Light Detection (ALD) settings and the room is too bright for the current light level setting |
| Problem: Lights turn off while space is occupied |
| Sensor's timeout may be too short |
| Sensor's sensitivity may be set for low |
| Sensor may not have full view of the room |
| Problem: Lights will not turn off once space is unoccupied |
| Sensor's timeout may be set for too long |
| An external noise such as an HVAC vent is interfering with the sensor. Try changing the sensitivity setting to low |
| Problem: Lights turn on in vacancy mode |
| A 15 second grace period follows the timeout, where the sensor will turn the lights back on if it senses motion
|