| For lighting loads only | 
 | Ground connection required | 
 | Neutral connection not required | 
 | Sensor can be bypassed to keep the lights on by extending the time out period to up to 30 minutes. Cannot override sensor so lights stay on indefinitely | 
 | Does not detect motion through glass | 
 | 
| Troubleshooting | 
 | Problem: Lights do not turn on when space is occupied | 
 | Check sensor is not in manual-on mode (vacancy mode) | 
 | Sensor may be set to auto-on daylight sensing (ALD) which will not turn the lights on if there is already a significant amount of light in the room | 
 | Problem: Lights turn off while space is occupied | 
 | Sensor's timeout may be too short | 
 | Sensor's sensitivity may be set for low | 
 | Sensor may not have full view of the room | 
 | Problem: Lights will not turn off once space is unoccupied | 
 | Sensor's timeout may be set for too long | 
 | An external noise such as an HVAC vent may be interfering with the sensor. Try changing the sensitivity sensing to low | 
 | Problem: Lights turn on in vacancy mode | 
 | In vacancy mode, a 15 second grace period follows the timeout where the sensor will turn the lights back on if it senses motion 
					 |